Reznor's PDH  is the new indoor, power-vented addition to the Reznor brand line of Pre-Engineered Ventilation Airhandlers (PREEVA).

Model PDH is available in 11 sizes from 75MBH to 400MBH. Each size is designed for a minimum 81% thermal efficiency and is available for use with either natural gas or propane. The model PDH can be configured for space conditioning or 100% outside air. You can also specify cooling coils for DX or chilled water or evaporative cooling.
Model PDH indoor, power-vented heaters are approved for commercial/industrial installations in the United States and Canada by the ETL Testing Agency.

Wärmeleistung ( MBH )

Kälteleistung ( MBH )

Luftvolumenstrom ( CFM )

Wirkungsgrad bei Vollast ( Bruto )

Standard

  • ETL certification
  • Minimum 81% thermal efficiency
  • Maximum 100 degree F temperature rise
  • Circuit breaker protected transformer for 24-volt controls
  • Integrated circuit board with diagnostic indicator lights
  • Multi-try direct ignition with 100% lockout
  • High temperature limit control
  • Vibration/noise isolated venter motor and blower motor
  • L50 ball bearings with 150,000 hour bearing life
  • Reverse airflow limit switch
  • Airflow pressure switch to verify circulating blower operation on makeup air options
  • Easily convertible single gas orifice system
  • Socketed, high quality switching relays to facilitate service
  • All service and vent connections from a single side
  • Vent runs up to 50 feet
  • Through-the-cabinet or through-the-base electrical
  • Engineered condensate management disposal system
  • Three hinged service doors with heavy duty hardware
  • Pre-coat RAL 9010 white paint finish
  • 4-pt base suspension; or slab or floor mounting
  • Fork lift openings built into the heavy gauge base

Factory-Installed Options

  • TCORE2® Titanium Stabilized Heat Exchanger -aluminized steel, 409 stainless steel, or 316 stainless steel (stainless steel heat exchanger required for 60° - 100°F temperature rise)
  • Heat Exchanger Extended Warranty - 5-year or 10-year
  • Natural Gas or Propane
  • Controls - Analog & Digital
    • Space Temperature Heating only
      • Analog single or two-stage gas valve with room thermostat control (thermostat is available as a shipped-separate accessory or may be field-supplied)
    • Space Temperature Heating/Cooling
      • Digital two-stage heating/three-stage cooling with room command module
      • Digital electronic modulation heating (33% low fire)/ two-stage cooling with room command module
    • Discharge Temperature Makeup Air
      • Analog 2-stage with 2-stage ductstat or electronic sensor and 2-stage valve; high fire/33% low fire
        modulating control
    • Discharge Temperature Heating/Cooling Makeup Air
      • Digital two-stage heating/three-stage cooling with room command module
      • Digital electronic modulation heating (33% low fire)/ two-stage cooling with room command module
  • Supply Voltage - 115/1; 208/1; 230/1; 208/3; 230/3; 460/3; 575/3
  • Unit mounted, lockable, non-fused service switch
  • Inlet Air Filters - 1" or 2" disposable or permanent; 1", 2", or 4" pleated disposable; arranged in vertical flat bank for ease of service
  • Cabinet Configuration and Construction
    • Left or right side controls
    • No insulation; single or double wall with standard or high R-value insulation
    • Blower cabinet screen
    • Inlet duct connection flange
    • Discharge duct flange or louvers (horizontal or horizontal and vertical)
  • Mixing Box Module with five inlet and discharge configuration combinations including top, bottom, and rear
    • with manual, motorized 2 or 3 position, or motorized modulating return air or outside air and return air dampers
    • with direct-coupled 24VAC damper actuators
    • with damper control selections such as 0-135 ohms resistance potentiometer, building pressure, or 0-10 v control
  • Blower Motor (1/4 to 5 HP) - see pressure drops and blower charts
    • Open dripproof, TEFC, premium efficiency, or 2-speed open dripproof
    • with adjustable sheave and linked or solid belt
    • with motor contactor; IEC motor starter; or factory-installed variable frequency drive
  • Cooling Coil Module -
    • with DX coil (single, dual or 1/3-2/3 circuit; galvanized or stainless casing; copper or aluminum fins (coated or uncoated))
    • with chilled water coil (3-45 tons; 1/4, 1/2, 3/4, or full circuiting; galvanized or stainless casing; copper or aluminum fins (coated or uncoated))
  • Evaporative Cooling Module -
    • with recirculating pump or AquaSaver timed water distribution
    • with 6" or 12" cellulose or UL cellulose media
    • with 1" aluminum pre-filter
  • Electronic Air Filter Module -
  • Convenience Outlet
  • Firestat
  • Discharge Temperature Low Limit
  • Over/Under Voltage or Phase Loss Protection
  • High Ambient Limit (burner cutoff)
  • Gas Pressure Switches (high, low, or both)

Field-Installed Options

  • Variable Frequency Drive (factory-installed is also available)
  • Downturn Nozzles (25-65 deg. or 50-90 deg. angle) with directional louvers
  • Thermostats to match analog controls
  • Gas Pressure Regulator
  • Smoke Detector (in ductwork)
  • Remote Control Console and Unit Monitoring
  • Main Unit Disconnect Switch
  • Fill and Drain or Freeze Protection Kit (for evaporative cooler)
  • Vent Cap

Broschüren
5 Dateien

Broschüren


English
Split System Marketing Catalog
Split Systems Marketing Catalog
Datei herunterladen
824.4 kB
Comp Edge: Superior Dehumidification with ReHeat Pump™
Advantages of using a ReHeat Pump vs. a hot gas reheat (HGRH) system
Datei herunterladen
126.5 kB
Comp Edge: The wide range of options and features of PreevA and the M-Series Condensing unit
Competitive Edge: The wide range of options and features of PreevA and the M-Series Condensing unit
Datei herunterladen
599.9 kB
Energy Edge: By matching building heating and cooling needs, the PreevA Series can save energy
Energy Edge: By matching a building heating and/or cooling needs (at full or part load), the PreevA Series can save energy and provide more consistent comfort levels
Datei herunterladen
486.7 kB
General Product Brochure
Overview brochure covering the Reznor product line.
Datei herunterladen
1.6 MB

Technische Daten
2 Dateien

Technische Daten


English
Catalog - Split System
Commercial split systems catalog
Datei herunterladen
3.4 MB
Sample Specs - PDH
Sample specifications for Model PDH (Word document)
Datei herunterladen
17.0 kB

Wartung / Installation
20 Dateien

Wartung / Installation


English
Unit Installation Manual - Indoor PreevA
Installation Manual for Models PDH, PEH, PXH, SDH & SHH
Datei herunterladen
2.0 MB
Parts Manuals - PreevA - Replacement Parts
Replacement parts for PreevA, Models PDH, PEH, PXH, RDH, REH, RHH, RXH, SDH, & SHH
Datei herunterladen
6.5 MB
Option - Installation - Downturn Nozzle Installation - Indoor PreevA
Installation of downturn nozzles for indoor PreevA units
Datei herunterladen
753.7 kB
Conversion Info - Gas Conversion - PreevA
Gas conversion kit instructions for Models PDH, SDH, & RDH with 1-stage gas control or 2-stage gas control
Datei herunterladen
351.7 kB
Option - Installation - Venting Instructions - PDH
Venting instructions for Model PDH
Datei herunterladen
500.7 kB
Option - Installation - UV Light Installation - PreevA
Instructions for installing the UV light for PreevA systems with a cooling coil
Datei herunterladen
339.5 kB
Option - Installation - Remote Display
Installation instructions for optional remote mounted display for PreevA & MAPS Series, and Model ZQYRA
Datei herunterladen
335.8 kB
Controls - PreevA D21 Control Manual
PreevA digital control D21, makeup air control for air hanlder systems.
Datei herunterladen
1.9 MB
Controls - PreevA D19 Control Manual
Digital controller D19 for space temperature control for PreevA air hanlder systems.
Datei herunterladen
1.9 MB
Parts Manuals - Functional Replacement Fan/Blower Controls and Limit Controls
 Parts manual for functional replacement fan/blower controls and limit controls
Datei herunterladen
322.8 kB
Parts Manuals - Replacement Ignition System and Gas Valves
Replacement ignition system and gas valves by serial number code and Maxitrol system components by serial number suffix
Datei herunterladen
964.6 kB
Operation - PreevA
Operation, maintenance and service manual for PreevA systems, Models SHH, RXH, RDH, REH, PXH, SDH, PDH, & PEH
Datei herunterladen
861.1 kB
Field Service - Field Adjustment of Control FX05 - PreevA
Application and instructions for field adjustment of the control (Model FX05) in digital control option DG1, DG2, DG5, & DG6
Datei herunterladen
1.7 MB
Field Service - Replacment Relay Kit - PN 262375
Replacement relay kit for Reznor part number 262375, applies to all power vented units using Reznor part number 206146 time delay relay
Datei herunterladen
1.2 MB
Field Service - Damper Motor Replacement
Instructions for replacement kit (261697) for Belimo damper motor
Datei herunterladen
161.8 kB
Field Service - Adjustment of Control FX06 - PreevA
Application and instructions for field adjustment of the contorl (Model FX06) in digital control options D12B, D12C, D12D, D12E, D12F, & D12G for PreevA units
Datei herunterladen
766.6 kB
Field Service - Repl Kits for Amplifier in Electronic Modulation
Replacement kits for Maxitrol Amplifier Options AG7, AG8, AG9
Datei herunterladen
293.8 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Datei herunterladen
340.4 kB
Français
Manuel d'installation - Intérieur PreevA
Manuel d'installation applicable aux: unités de traitement d'air modèle PDH, modèle SDH, modèle PEH, modèle PXH et modèle SHH
Datei herunterladen
3.8 MB
Opération - Série PreevA
Opération, maintenance et réparation PreevA ® Modèles RHH, SHH,  PDH, PEH, PXH, SDH, RDH, REH, et RXH
Datei herunterladen
2.2 MB

Andere Dateien
1 Datei

Andere Dateien


English
Warranty Statement
Reznor equipment limited warranty statement
Datei herunterladen
175.7 kB