Description

Reznor's SC separated combustion, gas-fired duct furnaces are designed to separate their combustion air from the air in the heated space.  The separated combustion furnace is designed for use in building areas with negative pressure and/or extremely dirty or mildly corrosive atmospheres.

As the leading pioneer in separated combustion technology; these units are designed and manufactured in accordance with the ANSI definition of "separate combustion". Using outside combustion air prevents dirt, lint, dust or other contaminants in the heated space from entering the combustion zone of the furnace. 

 Note: A specially designed combustion air inlet/vent terminal assembly supplied with SC series units requires only a single-building penetration for both exhaust and combustion air.

Capacité de chauffe ( MBH )

Débit d'air ( CFM )

Rendement à pleine charge ( PCS )

Standard

  • Orifices for natural gas
  • Aluminized steel heat exchanger
  • Aluminized burners with a stainless steel insert
  • 115 volt supply voltage
  • 115 volt venter motor with stainless steel shaft
  • 24 volt control voltage transformer
  • Redundant single-stage combination gas valve
  • Spark-ignited intermittent safety pilot with electronic flame supervision
  • High limit safety cutout
  • Post-purge control sequence
  • Terminal block wiring
  • Fan Control
  • Side access for burners and controls (slide-out burner drawer)
  • Threaded suspension couplings (2) for 1" pipe hangers

Optional Features - Factory Installed

  • Unit equipped for propane gas
  • E-3 (409) stainless steel heat exchanger
  • 321 stainless steel heat exchanger
  • E-3 stainless steel bottom drip pan
  • E-3 (409) stainless steel burner
  • Spark-ignited intermittent safety pilot with electronic flame supervision and timed lockout
  • Two-stage gas controls
  • Electronic modulation - 50%-100% firing rate
  • Electronic modulation gas control, 20/28%-100% firing rate - not available on size 350
  • Burner air shutters (required for units equipped for propane gas)
  • 208/230/460/volt/60/1 supply voltage
  • Manifold approved to meet Illinois school code
  • High and low gas pressure switches
  • Right side controls (facing air stream)

Optional Features - Field Installed

  • Condensate drain flange kit
  • Manual shut-off valve and union
  • Room override for electronic modulation with ductstat
  • Horizontal or vertical vent terminal/combustion air assembly - installation required
  • Single-stage thermostat
  • Thermostat guard with locking cover

Brochures
2 Fichiers

Brochures


English
Duct Heater Marketing Catalog
Duct Heater Marketing Catalog
Télécharger fichier
858.0 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
Télécharger fichier
607.6 kB

Données Techniques
1 Fichier

Données Techniques


English
Catalog - Duct Heater
Duct heater catalog
Télécharger fichier
1.6 MB

Service / Installation
23 Fichiers

Service / Installation


Français
Unit Installation Manual - Appareil de chauffage à combustion séparée, modèle SC
Appareil de chauffage à combustion séparée, modèle SC
Télécharger fichier
1.6 MB
English
Unit Installation Manual - Duct Furnace SC
Installation manual for Model SC
Télécharger fichier
1.6 MB
Parts Manuals - Separated Combustion - Parts Manual
Parts manual for Models SC & SSCBL
Télécharger fichier
2.1 MB
Field Service - Replacement Venter Motor and Mounting Plate
Instructions for assembling replacement venter motor and motor mounting plate for Models RP, RPB, RPBL, SC, & SSCBL
Télécharger fichier
361.6 kB
Option - Installation - Vent/Combustion Air Kits Installation
Instructions for installing vertical or horizontal vent/combustion air kits for separated combustion
Télécharger fichier
304.5 kB
Field Service - Replacement Gear Motor Kit
Instructions for installing replacement gear motor kit for Models SC, SSCBL, HRPD, RP, RPB & RPBL
Télécharger fichier
755.5 kB
Parts Manuals - Functional Replacement Fan/Blower Controls and Limit Controls
 Parts manual for functional replacement fan/blower controls and limit controls
Télécharger fichier
322.8 kB
Parts Manuals - Pilots - Parts manual
Functional replacement pilots
Télécharger fichier
394.4 kB
Conversion Info - High CFM Conversion - SC
High cfm conversion kit for Model SC
Télécharger fichier
359.5 kB
Parts Manuals - Replacement Ignition System and Gas Valves
Replacement ignition system and gas valves by serial number code and Maxitrol system components by serial number suffix
Télécharger fichier
1.3 MB
Conversion Info - Gas Conversion - Various Models
Gas conversion parts and instructions for various Reznor units
Télécharger fichier
1.5 MB
Field Service - Replacement Pressure Switch Kits
Replacement pressure switch kits for Models ADF, ADFH, RDF, SC, SSCBL,  and to Models RP, RPB, & RPBL manufactured in 1991 or later
Télécharger fichier
374.7 kB
Field Service - Replacment Relay Kit - PN 262375
Replacement relay kit for Reznor part number 262375, applies to all power vented units using Reznor part number 206146 time delay relay
Télécharger fichier
1.2 MB
Field Service - Ignition Control Replacement - Various Models
Ignition control replacement kit for pilot code 62, 63, 65, 66, & 84 (found in first set of digitis of serial number)
Télécharger fichier
250.4 kB
Option - Installation - Replacement for Discontinued Fan Control
Replacement kit for discontinued fan control, applies to duct furnaces and air handling systems with a Thermocore® heat exchanger
Télécharger fichier
368.5 kB
Option - Installation - Valve Kit - M8, U8, U9
Replacement kit for propane valve with serial number code M8, U8, or U9
Télécharger fichier
127.1 kB
Field Service - Repl Kits for Amplifier in Electronic Modulation
Replacement kits for Maxitrol Amplifier Options AG7, AG8, AG9
Télécharger fichier
293.8 kB
Field Service - Replacing Venter Restrictor Plate
Instructions for replacing a venter restrictor plate on a 409 stainless steel heat exchnager on Models SC, HSC, & SCA
Télécharger fichier
274.2 kB
Field Service - Replacement Relay Kit - PN 259521
Replacement relay kit for Reznor part number 259521 - applies to power vented units using Reznor part number 46233 or 259518 time delay relay
Télécharger fichier
646.2 kB
Field Service - Ignition Control Replacement - Duct Heaters
Replacement kit for ignition control for Models X and SC
Télécharger fichier
164.2 kB
Option - Installation - Valve Kit - M6
Replacement kit for natural gas valve with code M6
Télécharger fichier
120.5 kB
Option - Installation - Replacement Venter Post Purge Control
Replacement kit for discontinued venter post purge control - applies to Reznor power vented/separated combustion furnaces and air handlers manufactured before 1987
Télécharger fichier
221.3 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Télécharger fichier
340.4 kB

Autres Fichiers
1 Fichier

Autres Fichiers


English
Warranty Statement
Reznor equipment limited warranty statement
Télécharger fichier
183.4 kB