Produits Tubes radiants VR (Supprimé)

Média

VR
VR


Description

Replaced by VPS model-

Reznor's VR is a low intensity, tubular infrared heater. Low intensity tubular infrared heaters provide a single system that distributes heat evenly across a long distance. The VR uses a forced air draft which allows heat exchanger length up to 70 feet.

Versatile

  • Vented to outdoors horizontally or vertically
  • Unvented (provided there is sufficient ventilation)
  • Arranged for outside combustion air
  • Operated at 50 Hz or 60 Hz

Mounting configuration

  • Can be configured to heat in a variety of shapes
  • Polished reflectors can be mounted at an angle directing the heat

Easy installation and maintenance

  • Diagnostic indicator light
  • Sight glass for burner observation
  • External thermostat connections
  • Hinged service door

Robust

  • 16 gauge aluminized steel combustion chamber
  • Polished aluminum reflectors
  • Aluminized steel flue gas turbulators for maximum efficiency
  • Multi-try direct spark ignition system

Capacité de chauffe ( MBH )

Longueur ( Feet )

Standard

  • Natural gas operation
  • Full input rate for elevations to 2,000 ft
  • 115/1 supply voltage
  • Multi-try direct ignition with 100% lockout
  • Single-stage combination gas valve (field adjustable for operation to 10,000 ft elevation)
  • Pre-purge and post-purge
  • Differential air pressure switch to verify combustion air flow
  • Diagnostic indicator light
  • Sight glass for burner observation
  • External terminal board connection for 24-volt thermostat
  • Grounded, plug-in cord
  • 16-gauge aluminized steel combustion chamber (10 ft length)
  • High emissivity radiant tubes, 16-gauge HRS (10 ft lengths)
  • Compression coupling tube connections
  • Wire form hangers
  • Polished aluminum reflectors (10 ft lengths) that overlap for continuous reflector system
  • Aluminized steel flue gas turbulators for maximum efficiency
  • Horizontal or vertical venting
  • Painted cabinet
  • Transformer for 24-volt controls

 

Optional Features - Factory Installed

  • Single stage propane gas valve (field adjustable for operation to 10,000 ft elevation)
  • 208/1 supply voltage (models 50 - 175)
  • 230/1 supply voltage (models 50 - 175)

Optional Features - Field Installed

  • "U" heat exchanger tube with reflector
  • "L" heat exchanger tube(s) with reflector
  • 5-ft heat exchanger tube with reflector
  • Reflector end covers
  • Side shields
  • Hanger kit
  • Outdoor combustion air inlet kit
  • Dual vent kit
  • Multiple heater control for zoning up to 6 units
  • Flexible gas connector
  • High altitude field conversion kits (6,000 - 10,000 ft)
  • Unit-mounted thermostat bracket
  • Gas conversion kits (natural & propane)
  • Vent cap
  • Manual shutoff valve & union
  • Thermostat

 


Brochures
4 Fichiers

Brochures


English
Marketing Catalog - Infrared
Infrared Marketing Catalog
Télécharger fichier
1.1 MB
Cooling & Ventilation Product Line
Cooling & Ventilation Product Line Card
Télécharger fichier
466.7 kB
Heating & Ventilation Product Line
Heating & Ventilation Product Line Card
Télécharger fichier
553.6 kB
VRF Product Line
VRF Product Line Card
Télécharger fichier
369.1 kB

Service / Installation
15 Fichiers

Service / Installation


English
Option - Installation - Multiple Heater Control Installation
Installation instructions for multiple heater control system
Télécharger fichier
479.1 kB
Option - Installation - Thermostat Bracket (Unit Mounted) Assembly
Instructions for installing a unit mounted thermostat bracket
Télécharger fichier
304.1 kB
Parts Manuals - Replacement Ignition System and Gas Valves
Replacement ignition system and gas valves by serial number code and Maxitrol system components by serial number suffix
Télécharger fichier
1.3 MB
Unit Installation Manual - VR
Installation manual for Model VR
Télécharger fichier
1.3 MB
Conversion Info - Gas Conversion - Model VR
Gas conversion instructions for Model VR
Télécharger fichier
257.9 kB
Option - Installation - Hanger Kit - Model VR
Assembly instructions for hanger kit for Model VR
Télécharger fichier
118.7 kB
Option - Installation - Outside Air Kit - Model VR
Installation of outside combustion air inlet kit for Model VR
Télécharger fichier
300.9 kB
Option - Installation - Side Shield - Model VR
Instructions for installing optional side sheild for Model VR
Télécharger fichier
219.3 kB
Option - Installation - Turnbuckle Kit - Model VR
Assembly instructions for turnbuckle kit for suspending Model VR
Télécharger fichier
130.3 kB
Conversion Info - High Altitude Kit - Model VR
High altitude instructions for Model VR
Télécharger fichier
260.3 kB
Option - Installation - "L" Tube Installation - Model VR
Instructions for installing optional "L" tube heat exchanger on Model VR
Télécharger fichier
319.2 kB
Option - Installation - Reflector End Cover - Model VR
Assembly instructions for relfector end cover for Model VR
Télécharger fichier
165.3 kB
Option - Installation - Dual Vent Kit - Model VR
Instructions for installing a duel vent kit for Model VR
Télécharger fichier
2.7 MB
Option - Installation - "U" Tube Installation - Model VR
Installation instructions of "U" shaped tube, heat exchanger for Model VR
Télécharger fichier
299.3 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Télécharger fichier
340.4 kB

Autres Fichiers
1 Fichier

Autres Fichiers


English
Warranty Statement
Reznor equipment limited warranty statement
Télécharger fichier
183.4 kB